Changes

Jump to navigation Jump to search
413 bytes added ,  13:42, 1 May 2014
Line 30: Line 30:     
==Non-Surgical or Closed Technique==
 
==Non-Surgical or Closed Technique==
 +
[[File:Tooth Extraction 1.jpg|200px|right|thumb|Cutting the periodontal ligament fibres using either a luxator or elevator of appropriate size.]]
 +
[[File:Tooth Extraction 2.jpg|200px|right|thumb|Removing a tooth from its socket using extraction forceps.]]
 +
[[File:Tooth Extraction 3.jpg|200px|right|thumb|Sectioning a tooth from the furcation towards the cusp, from the buccal to lingual/palatal aspect of the tooth during an extraction.]]
 
This technique is used for all single rooted teeth or teeth that have been sectioned into individual roots.  
 
This technique is used for all single rooted teeth or teeth that have been sectioned into individual roots.  
   −
The gingival attachment is cut around the whole circumference of the tooth using a no.11 scalpel blade or a sharp luxator. Either a luxator or elevator of appropriate size is then inserted into the periodontal ligament space to cut the periodontal ligament fibres. (pic10) Once some space is created between the tooth and the bone, an elevator is used to work circumferentially around the tooth applying some apical and rotational pressure at an acute angle to the tooth root. Pressure should be applied for 10 seconds at a time to break down the periodontal ligament fibres. It is important that the tooth is not levered. Once the tooth is mobile it can be delivered from the socket using either fingers or extraction forceps. (pic11) It is important to use extraction forceps correctly to avoid root fracture. The forceps should be applied as low down the root as possible. The forceps are initially used in a rotational manner to break down any remaining fibres and when the tooth is able to rotate in both directions, the tooth can gently be pulled from the socket.  
+
The gingival attachment is cut around the whole circumference of the tooth using a no.11 scalpel blade or a sharp luxator. Either a luxator or elevator of appropriate size is then inserted into the periodontal ligament space to cut the periodontal ligament fibres. Once some space is created between the tooth and the bone, an elevator is used to work circumferentially around the tooth applying some apical and rotational pressure at an acute angle to the tooth root. Pressure should be applied for 10 seconds at a time to break down the periodontal ligament fibres. It is important that the tooth is not levered. Once the tooth is mobile it can be delivered from the socket using either fingers or extraction forceps. It is important to use extraction forceps correctly to avoid root fracture. The forceps should be applied as low down the root as possible. The forceps are initially used in a rotational manner to break down any remaining fibres and when the tooth is able to rotate in both directions, the tooth can gently be pulled from the socket.  
   −
To section teeth into individual roots a tapered fissure friction grip bur on a high speed handpiece with water-cooling should be used. A small diameter bur should be used. The furcation needs to be identified and as a general rule, lies below the main cusp of the crown. Once the furcation is identified the tooth should be sectioned from the furcation towards the cusp, from the buccal to lingual/palatal aspect of the tooth. (pic12) Care should be taken not to damage the gingival attachment at the furcation. To check that the tooth has been adequately sectioned, place an elevator between the two sections of the tooth and gently rotate – both parts of the crown should move independently.  
+
To section teeth into individual roots a tapered fissure friction grip bur on a high speed handpiece with water-cooling should be used. A small diameter bur should be used. The furcation needs to be identified and as a general rule, lies below the main cusp of the crown. Once the furcation is identified the tooth should be sectioned from the furcation towards the cusp, from the buccal to lingual/palatal aspect of the tooth. Care should be taken not to damage the gingival attachment at the furcation. To check that the tooth has been adequately sectioned, place an elevator between the two sections of the tooth and gently rotate – both parts of the crown should move independently.
    
==Surgical or Open Technique==
 
==Surgical or Open Technique==
Author, Donkey, Bureaucrats, Administrators
53,803

edits

Navigation menu