ELISA testing

WikiBloodWikiBlood Banner.png
IMMUNOLOGY
IMMUNOLOGICAL TESTING


Introduction

Double Antibody Sandwich ELISA

The Enzyme Linked Immunosorbent Assay (ELISA) is an immunoassay commonly used to detect the presence of an antigen or antibody in a sample. It is a powerful tool in clinical immunology and can be used to determine whether an individual has been exposed to a specified pathogen. Utilizing the principle of antigen-antibody interaction, the test allows easy visualisation of results and, since its introduction in 1971, has quickly replaced radioimmunoassays for diagnostic purposes.

  • There are two basic types of ELISA:
    • Homogenous- completed in one step, all reagents added simultaneously. Primarily used to detect small molecules such as digoxin and gentamicin
    • Heterogenous- various reagents added sequentially, primarily used to detect microbial antigens and antibodies

This article describes the heterogenous type

Applications

  • Detection and identification of disease agents, e.g. type and subtype
  • Identification of specific antibodies, e.g. used in serodiagnosis for epidemiological studies
  • Quantification of specific antibody isotypes, e.g. IgM/IgG ratio

Techniques

There are many methods of ELISA, but each assay involves these basic steps:

  • The adsorption of antibody/antigen to solid phase (the medium)
  • The addition of the chosen sample and reagents
  • Incubation and washing
  • The addition of enzyme-labeled antigen/antibody
  • The addition of a specific substrate

Competitive VS Non-competitive

  • As their name implies, competitive assays measure the competition between a pre-titrated (fixed amount) of labeled antigen and an unknown quantity of sample antigen in their affinity to an antibody. The process can be reversed to measure the competition between labeled and unlabeled antibody.
  • Competitive techniques:
    • Easier to quantify
    • Less likely to be influenced by contaminants
    • However they are more demanding with regard to the accuracy of the reagents and the purity of the labeled ligand
  • Non-competitive assays:
    • Errors in dispensing reagents have little effect on the result
    • Therefore they are easier to control and yield accurate results
    • However they are easily influenced by cross reactions and non-specific binding

Solid VS Fluid-phase

96-well microtiter plate, Copyright Jeffrey M. Vinocur 2006

An important consideration is the medium in which the assay is carried out, largely dependent on what is being tested:

  • Fluid-phase (in solution)
    • Main advantage is that the behaviour of molecules in solution is easier to predict
  • Solid-phase (surface of protein-binding material, e.g. plastic)
    • Easier to perform and more sensitive
    • The most widely used solid-phase is the 96-well microtiter plater, manufactured as PVC flexible plates or polystyrene rigid plates



Non-competitive ELISA

Double Antibody Sandwich (for antigen detection)

  1. Antibody is adsorbed onto solid phase
  2. Wash
  3. Sample is added- specific antigen binds to antibody
  4. Wash
  5. Enzyme-labeled specific antibody is added- attaches to bound antigen
  6. Wash
  7. Enzyme substrate is added

visualised product = amount of antigen in the sample

Antibody Class Capture Assay (for antibody detection)

  1. Class-specific antiglobulin is adsorbed onto solid phase
  2. Wash
  3. Sample is added- class-specific antibody in the sample binds to antiglobulin
  4. Wash
  5. Antigen is added- attaches to specific antibody
  6. Wash
  7. Enzyme-labeled antibody is added
  8. Wash
  9. Enzyme substrate is added

visualised product = amount of specific antibody in sample

Indirect Method (for antibody detection)

  1. Antigen is adsorbed onto solid phase
  2. Wash
  3. Sample is added- any specific antibody present in sample binds to antigen
  4. Wash
  5. Enzyme-labeled antiglobulin is added- attaches to antibody
  6. Wash
  7. Enzyme substrate is added

visualised product = amount of antibody in the sample

Competitive ELISA

Direct Antibody Competition (for antibody detection)

  1. Antigen is adsorbed onto solid phase
  2. Wash
  3. Enzyme-labeled antibody (pre-titrated- optimal colour development) and sample are added
  4. Wash
  5. Enzyme substrate is added

visualised product = amount of enzyme-labelled antibody

Direct Antigen Competition (for antigen detection)

  1. Antigen is adsorbed onto solid phase
  2. Wash
  3. Antigen in sample is incubated with enzyme-labelled antibody (again pre-titrated): this is directed against the antigen on the solid phase
  4. Wash
  5. Enzyme substrate is added

visualised product = amount of enzyme-labelled antigen