Changes

Jump to navigation Jump to search
696 bytes added ,  12:04, 4 September 2011
m
no edit summary
Line 1: Line 1:  
==Introduction==
 
==Introduction==
Electrocardiography is one of the most commonly found piece of monitoring equipment in modern veterinary practices. It detects the electrical activity of the heart through 3 electrodes. These electrodes are most commonly placed on the 2 forelimbs and the left hindlimb. The electrodes are attached to the patient via ECG pads (most commonly), crocodile clips (more common in horses) and transcutaneous needles (rare). Frequently, additional electrode gel or alcohol is required to improve contact between the patient and electrodes.  
+
Electrocardiography is one of the most commonly found piece of monitoring equipment in modern veterinary practices.
    
The ECG can determine the rate, rhythm and nature of cardiac depolarisation and repolarisation. It can also indicate changes in myocardial mass, conductivity between the heart and skin and the presence of metabolic abnormalities affect the heart.
 
The ECG can determine the rate, rhythm and nature of cardiac depolarisation and repolarisation. It can also indicate changes in myocardial mass, conductivity between the heart and skin and the presence of metabolic abnormalities affect the heart.
Indication of metabolic abnormalities affecting the myocardium
  −
Indication of alterations in conductivity between heart and skin
     −
To interpret an ECG it is necessary to understand the path of depolarisation through the heart:
+
==Recording an ECG==
The sino-atrial node depolarises spontaneously and this wave of depolarisation spreads through the atria. The impulse is then conducted through AV node slowly. Then it rapidly passes through the bundle of His and bundle branches, spreading through the ventricular myocardium. The myocardium then remains depolarised for a period before repolarising. This depolarisation and repolarisation are detected as potential differences on the skin surface - producing the classic shape of the ECG trace.  
+
The ECG detects the electrical activity of the heart through 3 electrodes. These electrodes are most commonly placed on the 2 forelimbs and the left hindlimb. An additional 'earth' electrode may be placed on the right hindlimb.
 +
 
 +
The electrodes are attached to the patient via ECG pads (most commonly), crocodile clips (more common in horses) and transcutaneous needles (rare). Any hair should be clipped to improve contact between the ECG pad and the skin. Pads should be secured with tape and additional electrode gel or alcohol should be used to improve contact between the patient and electrodes. The electrodes are connected to the ECG machine by colour-coded cables.
 +
 
 +
 
 +
'''The colour coding system:'''
 +
 
 +
<font color = "yellow">Yellow: Left forelimb
 +
 
 +
<font color = "red">Red: Right forelimb
 +
 
 +
<font color = "green">Green: Left hindlimb<font color = "black">
 +
 
 +
'''Black: Right hindlimb'''
 +
 
 +
 
 +
The ECG should be recorded in a calm and quiet environment. If the animal is stressed it may help to dim the lights. The patient should be kept as still and relaxed as possible as muscle tremors and movement can cause artifacts on the trace. Dogs should be placed in right lateral recumbency but positioning in a cat is less important. The cables should be positioned so that they do not drape over the animals chest as they can cause respiratory movement artifact. Electrical activity can cause interference on the ECG trace (known as 50Hz interference). To prevent this it should be taken on an insulated surface away from computers and fluorescent lighting and other electrical equipment.
 +
 
 +
Chemical restraint should be avoided if at all possible as this changes the ECG.  
    
==Reading an ECG Trace==
 
==Reading an ECG Trace==
    
An ECG supplies information about the electrical activity of the heart only. It indicates the heart rate and rhythm and can be used to detect any arrhythmias. It does not supply information about cardiac function. It is important to remember to treat the patient not the ECG!
 
An ECG supplies information about the electrical activity of the heart only. It indicates the heart rate and rhythm and can be used to detect any arrhythmias. It does not supply information about cardiac function. It is important to remember to treat the patient not the ECG!
 +
 +
To interpret an ECG it is necessary to understand the path of depolarisation through the heart:
 +
The sino-atrial node depolarises spontaneously and this wave of depolarisation spreads through the atria. The impulse is then conducted through AV node slowly. Then it rapidly passes through the bundle of His and bundle branches, spreading through the ventricular myocardium. The myocardium then remains depolarised for a period before repolarising. This depolarisation and repolarisation are detected as potential differences on the skin surface - producing the classic shape of the ECG trace.
    
[[Image:ECG.jpg|left|]]
 
[[Image:ECG.jpg|left|]]
 +
 +
 +
 +
    
<center>
 
<center>
Line 38: Line 61:       −
 
+
Six limb leads (ECG traces derived from a pair of electrodes) are produced from the reading of the four electrodes. These are named leads I, II, III, aVR, aLV, aVF.
 
+
The trace should always be read from left to right. Ideally it should be read from the start but if this is too difficult then the most recognisable portion should be identified and the trace read from this point.  and if it is hard to read then you should identify the
 
  −
 
  −
 
        Line 60: Line 80:       −
These 5 features should be assessed in every ECG that you interpret.
+
===An Abnormal ECG Trace===
    
The following questions should be asked when interpreting every ECG:
 
The following questions should be asked when interpreting every ECG:
   −
 
+
===='''Is E.C.G. of diagnostic quality?'''====
'''Is E.C.G. of diagnostic quality?'''
      
It is important that no artefact is present on the trace. Interference from electrical equipment and fluorescent lighting (50Hz interference) and movement should be prevented. The ECG should be calibrated for both paper speed and vertical sensitivity, and the trace should remain within the paper edges. All leads should be demonstrated.
 
It is important that no artefact is present on the trace. Interference from electrical equipment and fluorescent lighting (50Hz interference) and movement should be prevented. The ECG should be calibrated for both paper speed and vertical sensitivity, and the trace should remain within the paper edges. All leads should be demonstrated.
   −
 
+
===='''What is the heart rate?'''====
'''What is the heart rate?'''
      
Heart rate can be calculated using one of the following two methods:
 
Heart rate can be calculated using one of the following two methods:
Line 84: Line 102:  
Where multiple rhythms exist, the rate of all rhythms present should be calculated.
 
Where multiple rhythms exist, the rate of all rhythms present should be calculated.
    +
An high heart rate may be due to sinus tachycardia, supraventricular tachycardia, ventricular tachycardia and atrial fibrillation. A slow heart rate may be caused by sinus bradycardia, sinus arrhythmia, second or third degree AV block, atrial standstill and sinus arrest.
   −
'''What is the heart rhythm?'''
+
===='''What is the heart rhythm?'''====
   −
It is important to interpret whether the heart rate is regular or irregular, and if it is irregular whether it is regularly irregular or irregularly irregular.  
+
It is important to interpret whether the heart rate is regular or irregular. If it is irregular you should record whether it is regularly irregular or irregularly irregular.  
    +
===='''What is the mean electrical axis?'''====
   −
'''What is the mean electrical axis?'''
+
This figure is of limited value in small animals. It can give some indication of ventricular enlargement and the presence of intraventricular conduction defects.
   −
This figure is of limited value in small animals. It can give some indication of ventricular enlargement and the presence of intraventricular conduction defects.
+
===='''What are the individual complex measurements?'''====
    +
Changes in the morphology of the complexes are classed as a change in the shape, size or duration of the P wave, QRS complex or T wave. The magnitude and duration of deflections can be caused by hypertrophy of the myocardium, electrolyte abnormalities or an alterations in autonomic tone within the heart.
   −
'''What are the individual complex measurements?'''
+
You should record whether all the deflections are the same, as some variations may be normal.
   −
Changes in the morphology of the complexes are classed as a change in the shape, size or duration of the P wave, QRS complex or T wave. The magnitude and duration of deflections may be altered by regional changes in myocardial mass and alterations in conduction. This can be caused by hypertrophy of the myocardium, electrolyte abnormalities or an alterations in autonomic tone within the heart.
+
Variation in P-wave can be caused by a wandering pacemaker or atrial ectopy. Variation in QRS complexes may be caused by either variable conduction or electrical alternans.
   −
You should record whether all the deflections are the same, as some variations may be normal.  
+
No P to every QRS - this occurs when ventricular depolarisation follows an abnormal atrial depolarisation. This can be caused by premature ventricular or junctional complexes, sinus arrest with ventricular or junctional escape complexes, atrial standstill and atrial fibrillation.
   −
Variation in P-wave
+
No QRS to every P - this occurs the AV node fails to conduct impulses normally. This can be caused by second and third degree AV block.
May be normal - wandering pacemaker
  −
May indicate atrial ectopy
  −
P-wave should be positive in lead II
  −
Variation in QRS complex
  −
Some variation may be normal
  −
May indicate variable conduction
  −
May indicate electrical alternans
     −
No P to every QRS.
+
The shape of a complex can be used to identify the location of the origin of a rhythm disturbance. Complexes that originate in the ventricles are produce wide and bizarre QRS complexes, whereas complexes of atrioventricular origin are narrow and upright.
This means that the ventricular depolarisation has not been preceded by a normal atrial depolarisation
  −
Premature complexes
  −
Ventricular premature
  −
Junctional premature
  −
Sinus arrest with escape complexes
  −
Ventricular escape
  −
Junctional escape
  −
No organised atrial depolarisation
  −
Atrial standstill
  −
Atrial fibrillation
     −
No QRS to every P.
+
====Are they consistently and reasonably related?====
Failure of AV conduction
  −
Second degree AV block
  −
Intermittent failure of AV conduction
  −
Mobitz type I - Prolongation of P-R interval
  −
Mobitz type II - No prolongation of P-R interval
  −
Third degree AV block
  −
Complete failure of AV conduction
  −
Complete AV dissociation
     −
Consistently and reasonably related.
+
Abnormal P-R interval:
Marked variation in P-R intervals may suggest AV dissociation
+
A variable P-R interval is caused by atrioventricular dissociation. This occurs secondary to junctional and ventricular rhythm disturbances and third degree AV block.
Can occur with
  −
Ventricular rhythm disturbances
  −
Junctional rhythm disturbances
  −
Third degree AV block
     −
AV dissociation:
+
To calculate this the P-P, R-R and P-R intervals should all be measured. If the P-R interval is the only variable factor this is very suggestive of AV dissociation.
Map out P-P intervals, Map out R-R intervals, Map out P-R intervals
  −
If P-P interval is relatively consistent, R-R interval is relatively consistent but P-R interval is highly variable then you have Atrioventricular dissociation
  −
Where atrioventricular dissociation occurs the origin of the ventricular depolarisation must be within the ventricle or the AV junction
     −
Alterations in intervals:
  −
May reflect alterations in myocardial mass
  −
Increased P-wave amplitude may reflect right atrial enlargement
  −
Increased R-wave amplitude may reflect changes in ventricular myocardium
  −
Increased T-wave amplitude
  −
May occur with drugs, electrolyte and acid-base disturbances
  −
May be normal in dogs
      
Common problems:
 
Common problems:
Line 156: Line 138:  
Determining the origin of non-sinus depolarisations
 
Determining the origin of non-sinus depolarisations
 
Determining the significance of E.C.G. abnormalities which may be present.
 
Determining the significance of E.C.G. abnormalities which may be present.
  −
Abnormalities of generation or conduction of the depolarisation can arise for various reasons
  −
Intrinsic cardiac disease
  −
Hypoxia
  −
Autonomic influence
  −
Mechanical abnormalities
  −
Metabolic abnormalities
  −
Electrolyte disturbances
  −
Drugs
      
==Summary==
 
==Summary==
 
ECG is the most useful tool for assessment of cardiac rhythm.
 
ECG is the most useful tool for assessment of cardiac rhythm.
    +
==References==
   −
Normal organised pattern of depolarisation and repolarisation of the heart leads to regular detectable potential differences between points on skin surface
  −
  −
  −
*Is there a P for every QRS?
  −
*Is there a QRS for every P?
  −
*Are they all reasonably related?
  −
*Are they all the same?
  −
*Is rhythm regular or irregular?
  −
*Is the arrhythmia regularly irregular or irregularly irregular?
      
[[Category:Monitoring Anaesthesia]]
 
[[Category:Monitoring Anaesthesia]]
 
[[Category: To Do - Siobhan Brade]]
 
[[Category: To Do - Siobhan Brade]]
332

edits

Navigation menu