Method:
Method:
#Usually measured using the metacarpal and metatarsal artery, although the tail can also be used.
#Usually measured using the metacarpal and metatarsal artery, although the tail can also be used.
−
#Once a pulse has been detected, the doppler probe is placed over to check that it is audible and the probe is taped to the limb.
+
#Once a pulse has been detected, the doppler probe is placed in that position on the limb to check that it is audible and the probe canthen be taped to the limb.
#A cuff is selected and placed proximal to the doppler probe and attached to a manometer.
#A cuff is selected and placed proximal to the doppler probe and attached to a manometer.
#The cuff is inflated until the pulse is no longer audible on the doppler.
#The cuff is inflated until the pulse is no longer audible on the doppler.
−
#The cuff is the gently released and a reading is taken when the pulse becomes audible again.
+
#The cuff is gently released and a reading is taken when the pulse becomes audible again.
−
*The measurement is systolic pressure.
+
*This measures systolic pressure only.
−
*Cuff width should measure as 40% of the circumference of the limb being used.
+
*Cuff width should ideally be 40% of the circumference of the limb chosen for this method.
'''Advantages'''
'''Advantages'''
*Cheap and available in most practices.
*Cheap and available in most practices.
*Useful in hypotensive patients.
*Useful in hypotensive patients.
'''Disadvantages'''
'''Disadvantages'''
−
*Not very reliable in horses.
+
*Not a reliable method in horses.