| | ==Gas supply== | | ==Gas supply== |
| − | A supply of gas to an anaesthetic machine can be either from cylinders or a piped source. Gases that commonly used are oxygen, medical air and nitrous oxide. | + | A supply of gas to an anaesthetic machine can be either from cylinders or a piped source. Gases that are commonly used are oxygen, medical air and nitrous oxide. |
| | | | |
| | ===Cylinders=== | | ===Cylinders=== |
| Line 48: |
Line 48: |
| | | | |
| | [[Image:pressure gauge.jpg|right|thumb|125px|<small><center>Pressure Gauge</center></small>]] | | [[Image:pressure gauge.jpg|right|thumb|125px|<small><center>Pressure Gauge</center></small>]] |
| | + | |
| | ==Pressure Gauge== | | ==Pressure Gauge== |
| | Pressure gauges indicate the pressure of gas in the pipeline of cylinders. Depending on the age of the machine they may be found above the cylinder yoke, or on the front panel of the machine. They are colour-coded and calibrated for each gas/vapour. While this oxygen gauge measures the pressure within the cylinder, which is directly related to the contents of the cylinder, the nitrous oxide gauge measures the saturated vapour pressure of the gaseous nitrous oxide and so does not indicate the fullness of the cylinder, and will only start to show a drop in pressure as the liquid nitrous is running low. | | Pressure gauges indicate the pressure of gas in the pipeline of cylinders. Depending on the age of the machine they may be found above the cylinder yoke, or on the front panel of the machine. They are colour-coded and calibrated for each gas/vapour. While this oxygen gauge measures the pressure within the cylinder, which is directly related to the contents of the cylinder, the nitrous oxide gauge measures the saturated vapour pressure of the gaseous nitrous oxide and so does not indicate the fullness of the cylinder, and will only start to show a drop in pressure as the liquid nitrous is running low. |
| Line 55: |
Line 56: |
| | [[Image:Flowmeter.jpg|right|thumb|125px|<small><center>Flowmeters</center></small>]] | | [[Image:Flowmeter.jpg|right|thumb|125px|<small><center>Flowmeters</center></small>]] |
| | ==Flowmeters== | | ==Flowmeters== |
| − | Flowmeters are made up of a transparent tube with either a bobbin or ball, which float in the gas flow. The flow rate is marked on the tubing, and the gas flows around the bobbin or ball, where if the flow increases then the marker will rise indicating a higher flow rate. If a bobbin is present then the flow rate is read from the top of the bobbin whereas if a ball is present then the flow rate is read from the middle point of the ball. Again, flowmeters are often colour coded for the gas that they are controlling, with oxygen commonly being white, while nitrous oxide is blue. | + | Flowmeters are made up of a transparent tube with either a bobbin or ball, which float in the gas flow. The flow rate is marked on the tubing, and the gas flows around the bobbin or ball, where if the flow increases then the marker will rise indicating a higher flow rate. If a bobbin is present then the flow rate is read from the top of the bobbin whereas if a ball is present then the flow rate is read from the line of the equator. Again, flowmeters are often colour coded for the gas that they are controlling, with oxygen commonly being white, while nitrous oxide is blue. |
| | | | |
| − | Flowmeters are supported along with the vapourisers and some other components on the backbar of anaesthetic machines. | + | Flowmeters are supported along with the vapourisers and some other components on the backbar of anaesthetic machines. |
| | | | |
| | ==Common Gas Outlet== | | ==Common Gas Outlet== |