Once the fluid requirement is calculated, it is often necessary to calculate further the requirements per hour if using a drip pump, or mls per second if fluids are delivered through a giving set. This is done as follows: -
 
Once the fluid requirement is calculated, it is often necessary to calculate further the requirements per hour if using a drip pump, or mls per second if fluids are delivered through a giving set. This is done as follows: -
  
Requirement per hour = Requirement per day /60
+
The calculated fluid requirement is multiplied by the bodyweight of the individual patient to give the total amount of fluid required for that patient as ml/24hr period. This is then further calculated depending on whether a ddrip pump is used or fluid rate is adjusted manually as shown below.
  
Requirement per minute = Requirement per hour/60
+
<center>
 +
{| border="1" cellpadding="1"
 +
|-style="background:#B0E0E6; color:black"
 +
!Requirement per hour (ml/hr) = Requirement per day (ml/24hr) ÷ 60
  
Requirement per second = Requirement per minute /60
 
  
Drops per second = Requirement per second x Giving Set Factor
+
Requirement per minute (ml/min) = Requirement per hour (ml/hr) ÷ 60
  
 +
 +
Requirement per second (ml/s)= Requirement per minute(ml/min) ÷ 60
 +
 +
 +
Drops per second = Requirement per second (ml/s)x Giving Set Factor
 +
|}
 +
</center>
  
 
==Special Considerations==
 
==Special Considerations==

Revision as of 19:17, 12 April 2009



What is Fluid Therapy?

Fluid Therapy is the administration of fluids to a patient as a treatment or preventative measure. It can be administered via an intravenous, intraperitoneal and subcutaneous routes. 60% of total bodyweight is accounted for by the total body water. This can further be divided into intracellular or extracellular as shown below.

Body Compartments.jpg

Fluid therapy is indicated when there is a loss of fluid to any part of these compartments. The severity of the fluid loss, and the compartment which is has been lost from with influence the choice of fluid.

Indications

  • Hypotension
  • Hypovolemia
  • Electrolyte, metabolic and acid base disorders
  • Decreased oxygen delivery
  • Geriatric patients at risk of organ failure

Definitions

  • Osmosis is the net movement of water across a semi permeable membrane. The movement is caused by a concentration gradient due to different solute concentrations.
  • Osmotic Pressure is the pressure caused by the solutes within the solution. The solute concentration prevents water movement across the membrane.
  • Tonicity is the term used to compare the osmotic pressure of different solutions
    • A hypotonic solution is one that has an osmotic pressure lower than plasma.
    • A isotonic solution is one that has an osmotic pressure the same than plasma.
    • A hypertonic solution is one that has an osmotic pressure higher than plasma.

Types of Fluids

  1. Crystalloids
  2. Colloids
  3. Blood Products

Fluid Rate Calculations

When calculating the fluid requirements of a patient, there are 3 elements to consider -

  1. Replacement
  2. Maintainance
  3. Ongoing Losses

Replacements are calculated based on the level of dehydration. Dehydration is based upon clinical assessment of each individual patient. Most commonly, skin tent is used for assessment. To calculate the amount required for replacement within a 24 hour period, the percentage dehydration is used in the following calculation.


Replacement = % Dehydration x Bodyweight (kg) x 10


Maintainance is the basic rate which a patient requires during a 24 hour period. It is commonly calculated as 50ml/kg/24hr, or 2ml/kg/hr.


Ongoing losses are calculated based on a predicted fluid amount lost by a patient within a 24 hour period. Common losses include vomitting and diarrhoea. It is often helpful here if the owners are able to give a detailed history as this makes it easier to predict the pattern of losses. In some patients there may be no ongoing losses and so this step can be skipped. To calculate the fluid requirement, the following calculation is used.


Ongoing losses = Amount per loss (ml/kg) x Bodyweight (kg) x No. of losses


These calculations are then added together to allow for the total fluid requirement in a 24 hour period. It is important to assess these requirements on a daily basis as losses may be increased/reduceed for example.

Once the fluid requirement is calculated, it is often necessary to calculate further the requirements per hour if using a drip pump, or mls per second if fluids are delivered through a giving set. This is done as follows: -

The calculated fluid requirement is multiplied by the bodyweight of the individual patient to give the total amount of fluid required for that patient as ml/24hr period. This is then further calculated depending on whether a ddrip pump is used or fluid rate is adjusted manually as shown below.

Requirement per hour (ml/hr) = Requirement per day (ml/24hr) ÷ 60


Requirement per minute (ml/min) = Requirement per hour (ml/hr) ÷ 60


Requirement per second (ml/s)= Requirement per minute(ml/min) ÷ 60


Drops per second = Requirement per second (ml/s)x Giving Set Factor

Special Considerations

Anaesthesia

Pre-anaesthetic

Intra-anaesthetic

Post-anaesthetic

Cardiac

Central Nervous System