==Introduction== | ==Introduction== | ||
− | The radioimmunoassay (RIA) is a sensitive technique used to detect the presence of antigen in a sample using radiolabelled antibodies. Developed in the 1960's, the RIA proved a powerful tool in antigen detection, although the procedure was soon overtaken by ELISA, which | + | The radioimmunoassay (RIA) is a sensitive technique used to detect the presence of antigen in a sample using radiolabelled antibodies. Developed in the 1960's, the RIA proved a powerful tool in antigen detection, although the procedure was soon overtaken by ELISA, which utilise enzymes rather than radioactive labels. RIAs are still used today however, to measure: |
*Hormone levels in blood and tissue fluids | *Hormone levels in blood and tissue fluids | ||
*Serum proteins | *Serum proteins | ||
Line 8: | Line 19: | ||
==Principle== | ==Principle== | ||
− | *The general priniciple behind the RIA is the competitive binding of a | + | *The general priniciple behind the RIA is the competitive binding of a radiolabelled antigen and unlabelled antigen to a high-affinity antibody. |
− | * | + | *Labelled antigen is mixed with antibody until binding sites are saturated |
− | *Samples of | + | *Samples of unlabelled antigen (unknown concentration) are added in progressively increasing amounts |
**The two different antigens compete for the binding sites on the antibody | **The two different antigens compete for the binding sites on the antibody | ||
− | **As the concentration of | + | **As the concentration of unlabelled antibody increases, more labelled antigen will be displaced |
− | *The decrease in bound- | + | *The decrease in bound-radiolabelled antigen is measured- an indication of the amount of antigen present in sample |
==Technique== | ==Technique== | ||
− | *The antigen is often | + | *The antigen is often labelled with a gamma-emitting isotope, e.g. iodine-125 |
− | **Beta- | + | **Beta-emtting isotopes such as tritium are also often used |
− | # Determine the amount of antibody required to bind ~50% of | + | # Determine the amount of antibody required to bind ~50% of radiolabelled antigen in mixture- ''required to ensure the number of epitopes presented by labelled antigen exceeds number of antibody binding sites'' |
− | # Add | + | # Add unlabelled antigen to mixture |
# Separate antigen-antibody complex from free antigen by precipitation | # Separate antigen-antibody complex from free antigen by precipitation | ||
# Measure radioactivity in precipitate | # Measure radioactivity in precipitate | ||
*There are various methods to separate the antigen-antibody complexes from the free antigen: | *There are various methods to separate the antigen-antibody complexes from the free antigen: | ||
− | **Precipitate complexes using secondary isotype-specific | + | **Precipitate complexes using secondary isotype-specific antiimmunoglobulin |
− | **If complex contains | + | **If complex contains IgG, it can be removed by mixing with formalin-killed ''Staphylococcus aureus''- protein A of ''S. aureus'' has a high affinity for IgG |
− | *** Removal of the complex by either of these methods leaves an amount of free | + | *** Removal of the complex by either of these methods leaves an amount of free labelled antigen in the supernatant (liquid section from precipitation)- the radioactivity of this can be measured and the value taken away from the total amount of labelled antigen added (known amount)= amount of bound labelled antigen |
**A number of solid-phase RIAs have been developed | **A number of solid-phase RIAs have been developed | ||
− | ***Sometimes the antibody can be absorbed onto the surface- the amount of | + | ***Sometimes the antibody can be absorbed onto the surface- the amount of radiolabelled antigen bound to the beads can be measured after washing |
***Antibody can be immobilised on PVC or polystyrene | ***Antibody can be immobilised on PVC or polystyrene | ||
Line 35: | Line 46: | ||
**RIA used in this way has been employed in the detection of the hepatitis B surface antigen in donor blood, reducing the occurrence of hepatitis infections as a result of blood transfusions in humans | **RIA used in this way has been employed in the detection of the hepatitis B surface antigen in donor blood, reducing the occurrence of hepatitis infections as a result of blood transfusions in humans | ||
*Measuring plasma levels of hormones and controlled substances | *Measuring plasma levels of hormones and controlled substances | ||
− | *Measuring anti-DNA antibodies present in | + | *Measuring anti-DNA antibodies present in systemic lupus erythematosus (SLE) |
− | + | =Drawbacks= | |
Although the RIA is a very sensitive test, and therefore widely-used, there are disadvantages to its use: | Although the RIA is a very sensitive test, and therefore widely-used, there are disadvantages to its use: | ||
*The substances being used are radioactive | *The substances being used are radioactive | ||
Line 43: | Line 54: | ||
*Iodine is naturally concentrated in the thyroid gland, whether radioactive or not, and incorporated into thyroxine | *Iodine is naturally concentrated in the thyroid gland, whether radioactive or not, and incorporated into thyroxine | ||
Consequently, ELISA has largely overtaken RIA as a preferred diagnostic tool | Consequently, ELISA has largely overtaken RIA as a preferred diagnostic tool | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− |
Revision as of 08:43, 19 September 2008
This article has been peer reviewed but is awaiting expert review. If you would like to help with this, please see more information about expert reviewing. |
|
Introduction
The radioimmunoassay (RIA) is a sensitive technique used to detect the presence of antigen in a sample using radiolabelled antibodies. Developed in the 1960's, the RIA proved a powerful tool in antigen detection, although the procedure was soon overtaken by ELISA, which utilise enzymes rather than radioactive labels. RIAs are still used today however, to measure:
- Hormone levels in blood and tissue fluids
- Serum proteins
- Drugs
- Vitamins
- Levels can be detected when as low as 0.001 micrograms per millilitre, therefore this technique can be use to detect trace amounts of drug
Principle
- The general priniciple behind the RIA is the competitive binding of a radiolabelled antigen and unlabelled antigen to a high-affinity antibody.
- Labelled antigen is mixed with antibody until binding sites are saturated
- Samples of unlabelled antigen (unknown concentration) are added in progressively increasing amounts
- The two different antigens compete for the binding sites on the antibody
- As the concentration of unlabelled antibody increases, more labelled antigen will be displaced
- The decrease in bound-radiolabelled antigen is measured- an indication of the amount of antigen present in sample
Technique
- The antigen is often labelled with a gamma-emitting isotope, e.g. iodine-125
- Beta-emtting isotopes such as tritium are also often used
- Determine the amount of antibody required to bind ~50% of radiolabelled antigen in mixture- required to ensure the number of epitopes presented by labelled antigen exceeds number of antibody binding sites
- Add unlabelled antigen to mixture
- Separate antigen-antibody complex from free antigen by precipitation
- Measure radioactivity in precipitate
- There are various methods to separate the antigen-antibody complexes from the free antigen:
- Precipitate complexes using secondary isotype-specific antiimmunoglobulin
- If complex contains IgG, it can be removed by mixing with formalin-killed Staphylococcus aureus- protein A of S. aureus has a high affinity for IgG
- Removal of the complex by either of these methods leaves an amount of free labelled antigen in the supernatant (liquid section from precipitation)- the radioactivity of this can be measured and the value taken away from the total amount of labelled antigen added (known amount)= amount of bound labelled antigen
- A number of solid-phase RIAs have been developed
- Sometimes the antibody can be absorbed onto the surface- the amount of radiolabelled antigen bound to the beads can be measured after washing
- Antibody can be immobilised on PVC or polystyrene
Applications
- As the technique requires small amounts of sample it can be conducted on 96-well microtiter plates and large numbers of samples can be tested
- RIA used in this way has been employed in the detection of the hepatitis B surface antigen in donor blood, reducing the occurrence of hepatitis infections as a result of blood transfusions in humans
- Measuring plasma levels of hormones and controlled substances
- Measuring anti-DNA antibodies present in systemic lupus erythematosus (SLE)
Drawbacks
Although the RIA is a very sensitive test, and therefore widely-used, there are disadvantages to its use:
- The substances being used are radioactive
- Gamma radiation needs special counting equipment for detection
- Iodine is naturally concentrated in the thyroid gland, whether radioactive or not, and incorporated into thyroxine
Consequently, ELISA has largely overtaken RIA as a preferred diagnostic tool