Radioimmunoassay
Jump to navigation
Jump to search
This article has been peer reviewed but is awaiting expert review. If you would like to help with this, please see more information about expert reviewing. |
|
Introduction
The radioimmunoassay (RIA) is a sensitive technique used to detect the presence of antigen in a sample using radiolabelled antibodies. Developed in the 1960's, the RIA proved a powerful tool in antigen detection, although the procedure was soon overtaken by ELISA, which utilise enzymes rather than radioactive labels. RIAs are still used today however, to measure:
- Hormone levels in blood and tissue fluids
- Serum proteins
- Drugs
- Vitamins
- Levels can be detected when as low as 0.001 micrograms per millilitre, therefore this technique can be use to detect trace amounts of drug
Principle
- The general priniciple behind the RIA is the competitive binding of a radiolabelled antigen and unlabelled antigen to a high-affinity antibody.
- Labelled antigen is mixed with antibody until binding sites are saturated
- Samples of unlabelled antigen (unknown concentration) are added in progressively increasing amounts
- The two different antigens compete for the binding sites on the antibody
- As the concentration of unlabelled antibody increases, more labelled antigen will be displaced
- The decrease in bound-radiolabelled antigen is measured- an indication of the amount of antigen present in sample
Technique
- The antigen is often labelled with a gamma-emitting isotope, e.g. iodine-125
- Beta-emtting isotopes such as tritium are also often used
- Determine the amount of antibody required to bind ~50% of radiolabelled antigen in mixture- required to ensure the number of epitopes presented by labelled antigen exceeds number of antibody binding sites
- Add unlabelled antigen to mixture
- Separate antigen-antibody complex from free antigen by precipitation
- Measure radioactivity in precipitate
- There are various methods to separate the antigen-antibody complexes from the free antigen:
- Precipitate complexes using secondary isotype-specific antiimmunoglobulin
- If complex contains IgG, it can be removed by mixing with formalin-killed Staphylococcus aureus- protein A of S. aureus has a high affinity for IgG
- Removal of the complex by either of these methods leaves an amount of free labelled antigen in the supernatant (liquid section from precipitation)- the radioactivity of this can be measured and the value taken away from the total amount of labelled antigen added (known amount)= amount of bound labelled antigen
- A number of solid-phase RIAs have been developed
- Sometimes the antibody can be absorbed onto the surface- the amount of radiolabelled antigen bound to the beads can be measured after washing
- Antibody can be immobilised on PVC or polystyrene
Applications
- As the technique requires small amounts of sample it can be conducted on 96-well microtiter plates and large numbers of samples can be tested
- RIA used in this way has been employed in the detection of the hepatitis B surface antigen in donor blood, reducing the occurrence of hepatitis infections as a result of blood transfusions in humans
- Measuring plasma levels of hormones and controlled substances
- Measuring anti-DNA antibodies present in systemic lupus erythematosus (SLE)
Drawbacks
Although the RIA is a very sensitive test, and therefore widely-used, there are disadvantages to its use:
- The substances being used are radioactive
- Gamma radiation needs special counting equipment for detection
- Iodine is naturally concentrated in the thyroid gland, whether radioactive or not, and incorporated into thyroxine
Consequently, ELISA has largely overtaken RIA as a preferred diagnostic tool