Difference between revisions of "Automatic Disinfection and Flushing"

From WikiVet English
Jump to navigation Jump to search
 
(4 intermediate revisions by the same user not shown)
Line 1: Line 1:
 +
{{OpenPagesTop}}
 
Also known as: '''''ADF'''''
 
Also known as: '''''ADF'''''
  
Automatic Disinfection and Flushing (ADF) is a method of [[Post-Milking Teat Disinfection (PMTD)|post milking teat disinfection (PMTD)]] used in dairy cows for the control of contagious causes of mastitis. In addition to PMTD, the cluster is flushed between cows to further minimise the probability of infection being transferred between cows in the parlour. The flushing removes any milk residues within the liner that may be harbouring pathogens.  
+
==Introduction==
 +
 
 +
Automatic Disinfection and Flushing (ADF) is a method of [[Post-Milking Teat Disinfection|post milking teat disinfection (PMTD)]] used in dairy cows for the control of contagious causes of mastitis. In addition to PMTD, the cluster is flushed between cows to further minimise the probability of infection being transferred between cows in the parlour. The flushing removes any milk residues within the liner that may be harbouring pathogens.  
  
  
Line 7: Line 10:
  
  
The advantages of such a system over regular [[Post-Milking Teat Disinfection (PMTD)|PMTD]] is the timely application of disinfectant to the teat, good teat coverage, additional flushing of the unit, low disinfectant use (6-8ml per cow) and time efficiency for the operator. The disadvantages are the cost of installation and maintenance (including replacement of the specialised liners). It is also important that the system is set up correctly to ensure adequate, consistent disinfection.
+
The advantages of such a system over regular [[Post-Milking Teat Disinfection|PMTD]] is the timely application of disinfectant to the teat, good teat coverage, additional flushing of the unit, low disinfectant use (6-8ml per cow) and time efficiency for the operator. The disadvantages are the cost of installation and maintenance (including replacement of the specialised liners). It is also important that the system is set up correctly to ensure adequate, consistent disinfection.
  
  
Line 21: Line 24:
  
  
{{review}}
+
{{Nick Lyons written
[[Category:Expert Review - Farm Animal]][[Category:Mastitis]]
+
|date = April 18, 2011}}
 +
 
 +
{{OpenPages}}
 +
[[Category:Dairy Cow Management]]

Latest revision as of 18:20, 11 February 2013


Also known as: ADF

Introduction

Automatic Disinfection and Flushing (ADF) is a method of post milking teat disinfection (PMTD) used in dairy cows for the control of contagious causes of mastitis. In addition to PMTD, the cluster is flushed between cows to further minimise the probability of infection being transferred between cows in the parlour. The flushing removes any milk residues within the liner that may be harbouring pathogens.


The system works by having a specialised cluster unit and teat liner. The claw piece has an extra connection through which the disinfectant and flushing solution pass. The specialised liner has a valve located near the mouth of the liner. When the cow’s milk flow decreases to a certain level, this triggers the activation of an Automatic Cluster Removal (ACR) mechanism. At the same time a squirt of disinfectant comes out of the valve near the mouthpiece of the liner so that when the cluster is removed, this coats the teat with disinfectant. This process also disinfects the liner which is then flushed through with alternating water and compressed air to remove all residues that may be present. Removal of such residues is vital from a public health perspective by avoiding contamination of the bulk milk tank. Some systems perform the flushing component with peracetic acid.


The advantages of such a system over regular PMTD is the timely application of disinfectant to the teat, good teat coverage, additional flushing of the unit, low disinfectant use (6-8ml per cow) and time efficiency for the operator. The disadvantages are the cost of installation and maintenance (including replacement of the specialised liners). It is also important that the system is set up correctly to ensure adequate, consistent disinfection.


A simpler system that just performs the flushing component is also available (“Clusterflush”).

References and Further Reading

Biggs, A., 2009. Mastitis in Cattle, 1st Edition. The Crowood Press Ltd.

Blowey, R., Edmondson, P., 2010. Mastitis Control in Dairy Herds, 2nd Edition. CABI International.

http//:www.dairyco.co.uk




Error in widget FBRecommend: unable to write file /var/www/wikivet.net/extensions/Widgets/compiled_templates/wrt66512a2d749fc3_37161180
Error in widget google+: unable to write file /var/www/wikivet.net/extensions/Widgets/compiled_templates/wrt66512a2d785b51_97609127
Error in widget TwitterTweet: unable to write file /var/www/wikivet.net/extensions/Widgets/compiled_templates/wrt66512a2d7b93e2_49301182
WikiVet® Introduction - Help WikiVet - Report a Problem